    JHHS-HQ series SF6 mixed gas recovery and recharge purification and separation device
    • JHHS-HQ series SF6 mixed gas recovery and recharge purification and separation device

    JHHS-HQ series SF6 mixed gas recovery and recharge purification and separation device

    recommendation index:
    Adopt PLC controller, 15-inch color LCD touch screen
    Effective filtration and adsorption of decomposed impurities
    Liquid SF6 can be filled into cylinders for storage after separation and recovery
    High-efficiency filtration and maintenance-free system greatly guarantees the quality of recovered S
    • For rapid recovery, purification and separation of sulfur hexafluoride mixed gas

    • It is mainly composed of gas circuit system, vacuum system, evaporation and gasification system, gas pretreatment system, gas recovery and separation system, refrigeration liquefaction model system, exhaust gas treatment system, SF6 gas filling system, dynamic gas distribution system, pressurized gas charging system, gas detection system, gas storage tank and intelligent control system

    • Membrane separation technology or cryogenic solidification separation technology is used to separate the SF6 mixed gas, and the N2 gas is discharged into the atmosphere in a high-purity state after being cycled and infiltrated

    project

    Specifications

    Model

    JHHS10-HQ1

    JHHS20-HQ1

    JHHS30-HQ1

    Mixing ratio detection (built-in)

    Detect object

    SF6/N2

    Detection range

    0 pio 100% (volume fraction)

    Detection accuracy

    ± 0.5% (volume fraction)

    Resolution

    ± 0.01% (volume fraction)

    SF6 tail gas detection (built-in)

    Detection sensitivity

    ≤1μL/L

    Measurement error

    ≤±5%

    Vacuum pump

     

    Type

    Two-stage rotary vane vacuum pump with solenoid valve for preventing oil return.

    Vacuum flow

    ≥64m3/h

    ≥160m3/h

    ≥250m3/h

    Limit vacuum

    ≤10Pa

    Negative pressure recovery pump

    Negative pressure recovery rate

    ≥ 30m3/h

    ≥ 60m3/h

    ≥ 120m3/h

    Negative pressure recovery limit vacuum degree

    ≤100Pa


    Related recommendations

    JH6000HQ2-A4 SF6 gas mixture comprehensive detector

    Detection function, high accuracy, good stability

    JH6000HQ2-D4 SF6 Mixed Gas Comprehensive Detector

    Detection function, high accuracy, good stability

    JH6000HQ-3 SF6 gas mixing ratio detector

    Low air consumption, good for environmental protection

    Add wechat

    Scan and add customer service wechat

    亚洲精品aⅴ无码精品,亚洲天堂女人在线视频,国产亚洲日韩a欧美在线人成,97在线观看无码视频
  •