    JH6000HQ-D4 series  SF6 mixed gas comprehensive detector
    • JH6000HQ-D4 series  SF6 mixed gas comprehensive detector

    JH6000HQ-D4 series SF6 mixed gas comprehensive detector

     ?
    recommendation index:
    Detection function, high accuracy, good stability
    Portable design, fast testing, low air consumption, environmentally friendly
    Automatic flow control, efficient and accurate, effectively reducing sample gas emissions
    Users can use standard gas to self-calibrate the instrument
    • Detect the main decomposition products of insulation material cracking inside SF6 mixed gas electrical equipment: SO2 ,SOF2 , H2 S,CO,NO, N2 O,NF3 ,HF and other contents

    • Detect SF6 purity, SF6/N2 or SF6/CF4 mixing ratio, gas humidity in SF6 electrical equipment

    • JH6000HQ-D4 series SF6 mixed gas comprehensive detector, including JH6000HQ1-D4 (SF6/N2), JH6000HQ2-D4 (SF6/CF4) and JH6000HQ3-D4 (SF6/N2, SF6/CF4) and other models

    • NO, N2O, NF3 are optional

    name

    component

    parameter

    Model

    JH6000HQ1-D4

    JH6000HQ2-D4

    JH6000HQ3-D4

    minimum detectable quantity

    SO2+SOF2、H2S、HF

    ≤0.1μL/L

    CO、NO、N2O、NF3

    ≤0.5μL/L

    SF6

    ≤0.01%

    N2

    ≤0.01%

    \

    ≤0.01%

    CF4

    \

    ≤0.01%

    ≤0.01%

    O2

    ≤0.001%

    dew point

    ≤0.1℃

    precision

    SO2+SOF2、H2S、HF

    measurement value ≤ 10 μL/L, error≤±0.5 μL/L

    measured value > 10 μL/L, error±5%.

    CO、NO、N2O、NF3

    measurement value≤ 50 μL/L, error≤±2.0 μL/L

    measurement value > 50 μL/L, error≤±4%

    SF6

    Pure gas ≤ ± 0.1% (W/W)

    Air mix ≤ ± 0.5%

    N2

    ≤±0.5%

    \

    ≤±0.5%

    CF4

    \

    ≤±0.5%

    ≤±0.5%

    O2

    ≤±0.05%

    Dew point: resistance/mirror

    ≤±1℃/0.3℃

    repeatability

    SO2+SOF2H2S、HF

    measured value ≤ 10 μL/L, ≤ 0.2 μL/L

    10μL/L~100μL/L:2%.

    CO、NO、N2O、NF3

    measured value  ≤ 50 μL/L, ≤ 1.5 μL/L

    detection value 50 μL/L ~1000 μL/L: ≤ 3%

    SF6

    pure gas

    ≤0.05%(W/W,RSD)

    air mix

    ≤1.0%(RSD)

    O2

    ≤1.0%(RSD)

    N2

    ≤1.0%(RSD)

    \

    ≤1.0%(RSD)

    CF4

    \

    ≤1.0%(RSD)

    ≤1.0%(RSD)

    dew point

    1%

    range

    SO2+SOF2

    0~100μL/L,0~2000μL/L

    H2S

    0~100μL/L

    HF

    0~20μL/L

    CO、NO、N2O、NF3

    0~1000μL/L

    SF6

    0~100%

    N2

    0~100%

    \

    0~100%

    CF4

    \

    0~80%

    0~80%

    O2

    0~1%

    dew point

    -80 ℃~ + 20 ℃ (resistance and capacitance)/-60 ℃~ + 20 ℃ (mirror)

    gas flow rate

    Decomposition, mixing ratio

    200±5%mL/Min  

    moisture

    500±10%mL/Min   


    Related recommendations

    JHRX series, infrared thermal imaging cameras

    Expert-level native analysis capabilities assist in diagnosing equipment status

    JHSP-30 SF6 Portable Helium Ion Detector

    Highly integrated all-in-one design

    JHZW-100, UV Imager

    All-day blind ultraviolet imaging technology

    JHYQ-1 Rapid Detector for Dissolved Gas Acetylene in Oil

    Adopt the principle of electrochemical detection

    Add wechat

    Scan and add customer service wechat

    亚洲精品aⅴ无码精品,亚洲天堂女人在线视频,国产亚洲日韩a欧美在线人成,97在线观看无码视频
  •